Products >> flow-captor >> Insertion Flow Switch >> Flow Switch (Type 4114.--)
flow-captor: Flow Switch (Type 4114.--)
Technical Data

Water, Oil and Related Solutions
Flow Switch (Type 4114.--)
Flow Switch (Type 4114.--)
  • Full Range Set-Point Adjustment
  • A Wide Range of Pipe Sizes ³ 1 1/4 " (ID)
  • Easy Installation by a Welding Fitting
 
Technical Data
Type 4114.73 4114.70 SCP 4114.03
Medium Liquid and Pasty Media (Aggressive Media on Request)

Sensor Data
Set-Point Adjustable from 2 to 200 cm/s (Related to Water)
Set-Point Potentiom. Logarithmical to Flow Rate
Trip Point Deviation < 0.5% / K
Hysteresis < 15 %

Mechannical Data
Protection Class IP 65 / DIN 40050
Sensor Head
and Housing
Stainless Steel WN 1.4305 (V2A, 303),
Alternative: WN 1.4571 (V4A, 316 Ti)
Sensor Head Sealing FP (Viton)
Thread of Union Nut G 1 1/4 A SW 50 mm DIN 259 ISO 228
Pressure Max. 30 bar (435 PSI)
Medium Temp. -10°C to +80°C (14°F to 176°F)
Ambient Temp. -10°C to +60°C (14°F to 140°F)
Electrical Connection 2m Moulded Oilflex Cable
4 x 0.5 mm 2 3 x 0.5 mm 2

Electrical Data
Operating Voltage 90V - 265V AC/DC AC/DC 24 V ± 10% DC 24 V ± 10%
Switching Current Max. 150 mA Max. 200 mA
Power Consumption Max. 3W
LED 2-colored     Green: Flow Rate > Set-Point
                       Red:    Flow Rate < Set-Point
flow-captor
Insertion Flow Switch
Insertion Flow Meter
Inline Flow Switch
Inline Flow Meter
Flow and Temperature Sensors

 